Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Heart Fail ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734980

RESUMO

AIMS: Despite clear guideline recommendations for initiating four drug classes in all patients with heart failure (HF) with reduced ejection fraction (HFrEF) and the availability of rapid titration schemes, information on real-world implementation lags behind. Closely following the 2021 ESC HF guidelines and 2023 focused update, the TITRATE-HF study started to prospectively investigate the use, sequencing, and titration of guideline-directed medical therapy (GDMT) in HF patients, including the identification of implementation barriers. METHODS AND RESULTS: TITRATE-HF is an ongoing long-term HF registry conducted in the Netherlands. Overall, 4288 patients from 48 hospitals were included. Among these patients, 1732 presented with de novo, 2240 with chronic, and 316 with worsening HF. The median age was 71 years (interquartile range [IQR] 63-78), 29% were female, and median ejection fraction was 35% (IQR 25-40). In total, 44% of chronic and worsening HFrEF patients were prescribed quadruple therapy. However, only 1% of HFrEF patients achieved target dose for all drug classes. In addition, quadruple therapy was more often prescribed to patients treated in a dedicated HF outpatient clinic as compared to a general cardiology outpatient clinic. In each GDMT drug class, 19% to 36% of non-use in HFrEF patients was related to side-effects, intolerances, or contraindications. In the de novo HF cohort, 49% of patients already used one or more GDMT drug classes for other indications than HF. CONCLUSION: This first analysis of the TITRATE-HF study reports relatively high use of GDMT in a contemporary HF cohort, while still showing room for improvement regarding quadruple therapy. Importantly, the use and dose of GDMT were suboptimal, with the reasons often remaining unclear. This underscores the urgency for further optimization of GDMT and implementation strategies within HF management.

2.
Lancet ; 401(10394): 2113-2123, 2023 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-37220768

RESUMO

BACKGROUND: The effect of haemodynamic monitoring of pulmonary artery pressure has predominantly been studied in the USA. There is a clear need for randomised trial data from patients treated with contemporary guideline-directed-medical-therapy with long-term follow-up in a different health-care system. METHODS: MONITOR-HF was an open-label, randomised trial, done in 25 centres in the Netherlands. Eligible patients had chronic heart failure of New York Heart Association class III and a previous heart failure hospitalisation, irrespective of ejection fraction. Patients were randomly assigned (1:1) to haemodynamic monitoring (CardioMEMS-HF system, Abbott Laboratories, Abbott Park, IL, USA) or standard care. All patients were scheduled to be seen by their clinician at 3 months and 6 months, and every 6 months thereafter, up to 48 months. The primary endpoint was the mean difference in the Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary score at 12 months. All analyses were by intention-to-treat. This trial was prospectively registered under the clinical trial registration number NTR7673 (NL7430) on the International Clinical Trials Registry Platform. FINDINGS: Between April 1, 2019, and Jan 14, 2022, we randomly assigned 348 patients to either the CardioMEMS-HF group (n=176 [51%]) or the control group (n=172 [49%]). The median age was 69 years (IQR 61-75) and median ejection fraction was 30% (23-40). The difference in mean change in KCCQ overall summary score at 12 months was 7·13 (95% CI 1·51-12·75; p=0·013) between groups (+7·05 in the CardioMEMS group, p=0·0014, and -0·08 in the standard care group, p=0·97). In the responder analysis, the odds ratio (OR) of an improvement of at least 5 points in KCCQ overall summary score was OR 1·69 (95% CI 1·01-2·83; p=0·046) and the OR of a deterioration of at least 5 points was 0·45 (0·26-0·77; p=0·0035) in the CardioMEMS-HF group compared with in the standard care group. The freedom of device-related or system-related complications and sensor failure were 97·7% and 98·8%, respectively. INTERPRETATION: Haemodynamic monitoring substantially improved quality of life and reduced heart failure hospitalisations in patients with moderate-to-severe heart failure treated according to contemporary guidelines. These findings contribute to the aggregate evidence for this technology and might have implications for guideline recommendations and implementation of remote pulmonary artery pressure monitoring. FUNDING: The Dutch Ministry of Health, Health Care Institute (Zorginstituut), and Abbott Laboratories.


Assuntos
Insuficiência Cardíaca , Monitorização Hemodinâmica , Humanos , Idoso , Artéria Pulmonar , Monitorização Hemodinâmica/efeitos adversos , Qualidade de Vida , Insuficiência Cardíaca/tratamento farmacológico , Doença Crônica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...